Electrical

8 bulletins
10098351

THIS COMMUNICATION IS THE FINAL CUSTOMER NOTIFICATION FOR ADVISORY 16-273 FOR THE VOLTAGE GENERATOR HOUR METER.

10098350

THIS COMMUNICATION IS INFORMING DEALERSHIP SERVICE DEPARTMENTS OF ADVISORY 16-273 FOR THE VOLTAGE GENERATOR HOUR METER.

10098349

THIS ADVISORY 16-273 INVOLVES CERTAIN VOLTAGE FIFTH WHEELS.

Read full bulletin

IT HAS BEEN DETERMINED THAT ON SOME 2017 VOLTAGE MODELS THE GENERATOR HOUR METER WILL NOT TURN OFF DUE TO THE WIRES BEING CONNECTED INCORRECTLY ON THE BACKSIDE OF THE HOUR METER.

10097964

THIS COMMUNICATION IS THE FINAL CUSTOMER NOTIFICATION FOR ADVISORY 16-256 FOR THE VOLTAGE AIR CONDITIONER.

10097963

THIS COMMUNICATION IS INFORMING DEALERSHIP SERVICE DEPARTMENTS OF ADVISORY 16-256 FOR THE VOLTAGE AIR CONDITIONER.

10097245

THIS COMMUNICATION IS THE FINAL CUSTOMER NOTIFICATION FOR ADVISORY 16-258 FOR THE VOLTAGE ENERGY MANAGEMENT.

10097222

THIS COMMUNICATION IS INFORMING DEALERSHIP SERVICE DEPARTMENTS OF ADVISORY 16-258 FOR THE VOLTAGE ENERGY MANAGEMENT.

10097221

THIS ADVISORY 16-258 INVOLVES CERTAIN VOLTAGE FIFTH-WHEELS.

Read full bulletin

IT HAS BEEN DETERMINED THE ENERGY MANAGEMENT WAS WIRED INCORRECTLY CAUSING THE SYSTEM NOT TO SHED LOADS ON CERTAIN EPIC SERIES UNITS.

HVAC & Climate

3 bulletins
10097962

THIS ADVISORY 16-256 INVOLVES UNITS MANUFACTURED WITH CERTAIN AIR CONDITIONERS MAY NOT HAVE BEEN INSTALLED OVER THE...

Read full bulletin

OPENING CORRECTLY RESULTING IN A POSSIBLE ROOF LEAK. THE AIR CONDITIONER MUST BE INSPECTED AND IF NECESSARY, RE-ATTACHED TO THE ROOF.

10097252

REVISION MADE IN JULY 7, 2016, CLARIFIED THIS APPLIES TO THE AIR CONDITIONER ABOVE THE MAIN LIVING AREA.

Read full bulletin

THIS COMMUNICATION IS INFORMING DEALERSHIP SERVICE DEPARTMENTS OF REVISION TO ADVISORY 16-256, UNITS MANUFACTURED WITH CERTAIN AIR CONDITIONERS MAY NOT HAVE BEEN INSTALLED OVER THE OPENING CORRECTLY RESULTING IN A POSSIBLE ROOF LEAK. THE AIR CONDITIONER MUST BE INSPECTED AND IF NECESSARY, RE-ATTACHED TO THE ROOF.

10097251

REVISION MADE IN JULY 7, 2016, CLARIFIED THIS APPLIES TO THE AIR CONDITIONER ABOVE THE MAIN LIVING AREA.

Read full bulletin

THIS ADVISORY 16-256 INVOLVES UNITS MANUFACTURED WITH CERTAIN AIR CONDITIONERS MAY NOT HAVE BEEN INSTALLED OVER THE OPENING CORRECTLY RESULTING IN A POSSIBLE ROOF LEAK. THE AIR CONDITIONER MUST BE INSPECTED AND IF NECESSARY, RE-ATTACHED TO THE ROOF

Transmission

2 bulletins
10169048

Letter to dealers for KSB-191007.

Read full bulletin

This process describes the repair where under certain temperature conditions the Norco slide cable system gearbox may leak oil/grease on the slide roof membrane. The KSB describes how to install a drip pan to prevent damage to the roof membrane, and make repairs if necessary.

10169047

This is the repair instructions for KSB-191007.

Read full bulletin

This process describes the repair where under certain temperature conditions the Norco slide cable system gearbox may leak oil/grease on the slide roof membrane. The KSB describes how to install a drip pan to prevent damage to the roof membrane, and make repairs if necessary.