2018 Dutchmen Coleman TSBs

6 Technical Service Bulletins across 4 categories

Transmission

2 bulletins
10169048

Letter to dealers for KSB-191007.

Read full bulletin

This process describes the repair where under certain temperature conditions the Norco slide cable system gearbox may leak oil/grease on the slide roof membrane. The KSB describes how to install a drip pan to prevent damage to the roof membrane, and make repairs if necessary.

10169047

This is the repair instructions for KSB-191007.

Read full bulletin

This process describes the repair where under certain temperature conditions the Norco slide cable system gearbox may leak oil/grease on the slide roof membrane. The KSB describes how to install a drip pan to prevent damage to the roof membrane, and make repairs if necessary.

Electrical

2 bulletins
10153025

This is the REVISED repair instructions for advisory 18-318.

Read full bulletin

It has been determined that certain Atwood furnace models may have wiring that can come in contact with the exhaust vent tube causing the furnace to shut down in a safe manner.

10145525

This is the repair instructions for advisory 18-318.

Read full bulletin

It has been determined that certain Atwood furnace models may have wiring that can come in contact with the exhaust vent tube causing the furnace to shut down in a safe manner. This is the communication to the dealership regarding advisory 18-318 for certain Atwood furnace models. This is the final owner notification for adviosry 18-318, for certain Atwood furnace models. This is the revised repair instructions for advisory 18-318 for certain Atwood furnace models.

HVAC & Climate

1 bulletin
10119398

This is the repair instructions for advisory 17-295.

Read full bulletin

It has been determined some 2017-2018 Zinger single axle models were built with an in-wall air conditioner that has a potential to leak inside of the unit. This communication is the final Customer Notification for advisory 17-295 for the Zinger in-wall air conditioner. This communication is informing dealership service departments of advisory 17-295 for the Zinger in-wall air conditioner.

Lighting

1 bulletin
10119397

This is the repair instructions for advisory 17-294.

Read full bulletin

It has been determined that on some 2017-2018 Coleman 1755 models built in plant 840, a furnace return vent was not installed. This communication is the final Customer Notification for advisory 17-294 for the furnace return vent. This communication is informing dealership service departments of advisory 17-294 for the furnace return vent.