Powered byNHTSA|EPA|Community Reports|Updated
HomeTSBsBlue Bird2023 Vision Transit Bus

2023 Blue Bird Vision Transit Bus TSBs

7 Technical Service Bulletins across 4 categories

Engine

4 bulletins
10244319

Revised: Coolant leaks at the transmission cooler fittings on the radiator are occurring due to deformation of the...

Read full bulletin

gasket used to seal off the transmission cooler. This deformation is caused from transmission oil wicking through the thread adapter threads and exposing the lower portion of the gasket to transmission oil. Re-configure hydraulic interface between the transmission cooler lines and the transmission oil cooler. SU2302 Revised to include Labor Time of 1 Hour and a Component Code. Incorrect wording on the Header Page beginning on Page 2.

10244318

Revised: Coolant leaks at the transmission cooler fittings on the radiator are occurring due to deformation of the...

Read full bulletin

gasket used to seal off the transmission cooler. This deformation is caused from transmission oil wicking through the thread adapter threads and exposing the lower portion of the gasket to transmission oil. Re-configure hydraulic interface between the transmission cooler lines and the transmission oil cooler. SU2302 Revised to include Labor Time of 1 Hour and a Component Code.

10244309

Coolant leaks at the transmission cooler fittings on the radiator are occurring due to deformation of the gasket used to...

Read full bulletin

seal off the transmission cooler. This deformation is caused from transmission oil wicking through the thread adapter threads and exposing the lower portion of the gasket to transmission oil. Re-configure hydraulic interface between the transmission cooler lines and the transmission oil cooler.

10217921

Cummins recently issued Temporary Repair Practice (TRP2484) for certain vehicles with DEF sensor failures in which DEF...

Read full bulletin

sensor replacement parts are not available. This provides a temporary ECM calibration that inhibits engine warning messages for communication errors with the DEF sensor allowing continued operation without engine derate. Regulators are allowing for this temporary calibration to be loaded in the engine ECM by a Cummins authorized repair location if the DEF sensor fails. This temporary calibration does not repair the failure therefore a final repair must be performed and the original calibration be re-installed. Field Service has been requesting an ECM image be uploaded within the support ticket as part of the diagnostics and is carried over into Service Update 2201 (SU2201). In order to receive an authorization code and utilize Cummins TRP2484, you must follow the process, as outlined in SU2201. The specific component affected is Assembly Code: 35-300 Emissions Components.

Brakes

1 bulletin
11029074

The mechanical brake switch & bracket design has a potential for cumulative at-limit stack up clearances to exceed the...

Read full bulletin

limitations of the mechanical switch. As a result, a preventative maintenance adjustment procedure is necessary and, at times, settings can be difficult to achieve.

Transmission

1 bulletin
11010783

The 7.3L radiator uses adapter nuts, if not properly sealed, exposes the opportunity for fluid migration through threads.

Read full bulletin

Primary failure seen is deterioration of the EPDM gasket sealing the transmission oil cooler (TOC) to lower radiator tank, which allows a path for coolant to leak externally. Secondary failure seen is cross contamination between coolant and transmission oil. To eliminate the possibility of experiencing this condition, Blue Bird is providing 1 year of coverage to update the transmission oil cooler interface along with a visual inspection of any cross contamination at time of completing the interface update. Please follow the flowchart within the instructions to determine if any additional repair activity is necessary and, if so, complete further repair procedures as stated.

Electrical

1 bulletin
10210253

This document provides information on the cluster software improvement to address symptoms of acceptable parasitic...

Read full bulletin

battery loss attributed to CAN Devices not going to sleep. This symptom is occasionally accompanied by the cluster flashing on/off on an approximately 3-minute frequency. Blue Bird and Ametek have developed a software to alleviate this concern.